You will typically need three things to place an order: brand name, part/model numbers, and any related sizing information. One way to perform a quick check on efficiency is through flame port and stack temperature checks. Typically, a flame that is blue in color and a stack temperature that has not deviated greatly from daily records is ideal for efficiency. For further analysis, a Matt Marshall technician can perform combustion analysis testing and tune your boiler if necessary.
What do I need to place a parts order?
Is my boiler operating efficiently?
Engineering Data
Steam Pressure (PSI) |
Temperature (°F) |
---|---|
0 | 212 |
2 | 218 |
6 | 230 |
10 | 239 |
25 | 267 |
30 | 274 |
40 | 287 |
50 | 298 |
100 | 338 |
120 | 350 |
150 | 366 |
200 | 388 |
Equivalents | |
---|---|
No. 6 Oil | 151-155,000 BTU / GAL |
1 cu.ft. natural gas |
1000 BTU |
1 cu.ft. LP gas |
2500 BTU |
1 lb. steam | 1000 BTU |
1 EDR | 240 BTU |
1 BHP | 33.479 BTU / HR |
1 BHP | 34.5 lbs steam |
1 BHP | 4.15 gal. water |
1 gal. water | 8.33 lbs |
1 cu.ft. | 7.48 gal. |
Energy Loss from Scale Deposits in Boilers | |
---|---|
Scale Thickness (inches) | Extra Fuel Cost (%)* |
1/64 | 3.6 |
1/32 | 7.2 |
1/25 | 9.3 |
1/20 | 11.1 |
1/16 | 12.6 |
1/8 | 25.0 |
*Based on US Bureau of Standards and US Bureau of Mines |